Early Suppression, Fast Response Sprinkler K=25.2

ESFR-25
The Model ESFR-25 Pendent Sprinklers (Ref. Figure 1) are “Early Suppression Fast Response Sprinklers” having a nominal K-factor of 25.2.They are suppression mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers, when protecting high-piled storage.

Click here for PDF


     Early Suppression, Fast Response Pendent K=16.8

ESFR-17
The Model ESFR-17 Upright Sprinklers (Ref. Figure 1) are “Early Suppression Fast Response Sprinklers” having a nominal K-factor of 16.8.They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers, when protecting rack storage.

Click here for PDF


     Early Suppression, Fast Response Upright K=16.8

ESFR-17
The Model ESFR-17 Pendent Sprinklers (Ref. Figure 1) are “Early Suppression Fast Response Sprinklers” having a nominal K-factor of 16.8.They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers, when protecting rack storage.

Click here for PDF


     Early Suppression, Fast Response Sprinkler K=14.0

ESFR-1
The Model ESFR-1 Pendent Sprinklers (Ref. Figure 1) are “Early Suppression Fast Response Sprinklers” having a nominal K-factor of 14.0.They are suppression mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers, when protecting high-piled storage.

Click here for PDF


     Upright Specific Application K=16.8

Ultra K17
The 16.8 K-factor, Ultra K17, Standard Response, Upright Specific Application Control Mode Sprinklers (Ref. Figure1) are automatic sprinklers of the frangible bulb type. They are intended for use with National Fire Protection Association and Factory Mutual Research Corporation “specific application control mode” installation criteria for the protection of high piled storage. The Ultra K17 Sprinklers can provide a higher level of protection than standard spray sprinklers and, in some cases, they can provide an economical advantage by eliminating in-rack sprinklers.

Click here for PDF


     Pendent & Upright K=16.8

K17-231
The 16.8 K-factor, Model K17-231, Standard Response, Standard Coverage, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the frangible bulb type. They are “standard response - spray sprinklers” which produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Upright & Pendent K=11.2

ELO-231
The 11.2 K-factor, Series ELO-231, Standard Response, Standard Coverage, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the fusible solder type. They are “standard response - spray sprinklers” that produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Upright & Pendent K=11.2

ELO-231B
The 11.2 K-factor, Series ELO-231B, Standard Response, Standard Coverage, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the frangible bulb type. They are “standard response - spray sprinklers” that produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Upright & Pendent K=11.2

ELO-231 FRB
The 11.2 K-factor, Series ELO-231FRB, Quick Response, Standard Coverage, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the frangible bulb type. They are “quick response - spray sprinklers” that produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Large Drop Upright K=11.2

LD
The 11.2 K-factor, Model LD Upright Large Drop Sprinklers are glass bulb type automatic sprinklers. They are a type of specific application control mode sprinkler intended for use with National Fire Protection Association “large drop sprinkler" installation criteria for the protection of high piled storage. The LD Sprinklers can provide a higher level of protection than standard spray sprinklers and, in some cases, they can provide an economic advantage by eliminating in-rack sprinklers.

Click here for PDF


     5mm Bulb Intermediate Level Upright w/Shield K=5.6 & K=8.0

TY-B
The Series TY-B, 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers described in this data sheet are automatic sprinklers of the “standard response” 5 mm frangible bulb type. They are “standard spray” sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright sprinklers produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     3mm Bulb, Quick Response Intermediate Level Upright w/Shield K=5.6 & K=8.0

TY-FRB
The Series TY-FRB, 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers described in this data sheet are automatic sprinklers of the “quick response” 3 mm frangible bulb type. They are “standard spray” sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright sprinklers produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Standard Response Intermediate Level Upright w/Shield K=5.6 & K=8.0

TY-L
The Series TY-L, 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers described in this data sheet are automatic sprinklers of the “standard response” solder type. They are “standard spray” sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright Sprinklers produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


     Intermediate Level Upright Sprinkler w/Shield K=5.6 & K=8.0

TY-FRL
The Series TY-FRL, 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers described in this data sheet are automatic sprinklers of the “quick response” solder type. They are “standard spray” sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA requirements). Both the Pendent and Upright Sprinklers produce a hemispherical water distribution pattern below the deflector.

Click here for PDF


Fire Sprinklers Commercial | Fire Sprinklers Dry | Fire Sprinklers Emergency Service | Fire Sprinklers Extended Coverage
Fire Sprinklers Flexhead | Fire Sprinklers FAQ's | Fire Sprinklers Nozzles & Accessories | Fire Sprinklers Project Gallery
Fire Sprinklers Residential | Fire Sprinklers Residential Heads | Fire Sprinklers Resource | Fire Sprinklers Retrofit
Fire Sprinklers Schedule Service Online | Fire Sprinklers Standard Spray | Fire Sprinklers Storage
Fire System Deluge Systems & Valve Accessories | Fire System Dry | Fire System General Purpose Valves
Fire Systems Quick Opening Valves | Fire Systems Wet System Water Motor Alarm
Vanport Awards & Certifications | Contact Us | Directions | Vanport Entrance | Vanport Testimonials

Click here to the main entrance of www.TC-VP.com site. Click here to enter the HVAC division of our company. Click here to enter the Fire Sprinkler & Mechanical division of our company. hearth_patio_index.html" title="Click here to enter the Hearth & Patio division of our company.