Concealed Residential Sprinkler

FlameGuard CPVC
Fire Sprinkler
Head Adapter
Spears® Patented SR Female Plastic Thread design for FlameGuard CPVC Fire Sprinkler Head Adapters is now even more user-friendly. This advanced technology now incorporates a high-strength zinc alloy collar with wide wrench fl ats where needed most for installing fi re sprinkler heads and a patented metal starting thread that virtually eliminates accidental cross threading. Patented design contains expansion stress in make up of tapered-thread joints to prevent splitting of female plastic thread. Available in 3/4”x1/2” and 1”x1/2” Female Sprinkler Head Adapters.

Click here for PDF


     Concealed Residential Sprinkler

RFC43
Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge.

Click here for PDF


     Low Flow Pendent k=6.9

LFII
The Series LFII (TY4234) Residential Pendent, Recessed Pendent, and Concealed Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When enhanced flow characteristics for residential portions of any occupancy per NFPA 13 is the major consideration, the Series LFII (TY4234) should be the first choice.

Click here for PDF


     Low Flow Pendent K=4.9

LFII
The Series LFII (TY2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major consideration, the Series LFII (TY2234) should be the first choice.

Click here for PDF


     Low Flow Sidewall (Horizontal Sidewall) K=4.2

LFII
The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels.When aesthetics and optimized flow characteristics are the major consideration, the Series LFII (TY1334) should be the first choice.

Click here for PDF


     Residential Concealed Pendent Sprinkler, Domed Plate K=4.9

LFII
The Series LFII (TY2234) Residential Concealed Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels.

Click here for PDF


     Residential Concealed Sprinkler K=4.2

LFII
The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels.

Click here for PDF


     Residential Flush Pendent K=4.2

LFII
The Series LFII (TY2284) Residential Flush Pendent Sprinklers are decorative, fast response, fusible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics is the major consideration, the Series LFII (TY2284) should be the first choice.

Click here for PDF


     Residential Flush Sidewall (Horizontal Sidewall) K=4.2

LFII
The Series LFII (TY2384) Residential Flush Horizontal Sidewall Sprinklers are decorative, fast response, fusible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When esthetics is the major consideration, the Series LFII (TY2384) should be the first choice.

Click here for PDF


     Residential Sidewall (Horizontal Sidewall) K=5.6

LFII
The Series LFII (TY3334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When enhanced flow characteristics for residential portions of any occupancy per NFPA 13 is the major consideration, the Series LFII (TY3334) should be the first choice.

Click here for PDF


Fire Sprinklers Commercial | Fire Sprinklers Dry | Fire Sprinklers Emergency Service | Fire Sprinklers Extended Coverage
Fire Sprinklers Flexhead | Fire Sprinklers FAQ's | Fire Sprinklers Nozzles & Accessories | Fire Sprinklers Project Gallery
Fire Sprinklers Residential | Fire Sprinklers Residential Heads | Fire Sprinklers Resource | Fire Sprinklers Retrofit
Fire Sprinklers Schedule Service Online | Fire Sprinklers Standard Spray | Fire Sprinklers Storage
Fire System Deluge Systems & Valve Accessories | Fire System Dry | Fire System General Purpose Valves
Fire Systems Quick Opening Valves | Fire Systems Wet System Water Motor Alarm
Vanport Awards & Certifications | Contact Us | Directions | Vanport Entrance | Vanport Testimonials

Click here to the main entrance of www.TC-VP.com site. Click here to enter the HVAC division of our company. Click here to enter the Fire Sprinkler & Mechanical division of our company. hearth_patio_index.html" title="Click here to enter the Hearth & Patio division of our company.